AC-DC Modules Test Report

In this blog, we will test two AC-DC modules output situations. The test aims to examine the output ripple of each AC-DC module under the circumstance of different load current. These two modules all can be sold on ITEAD’s imall. 

AC-DC module 5V 700mA V1

AC-DC module 5V 700mA V2

Test1: AC Input 220V 50Hz without any filter capacitor accessing

The table below shows the relation of the output ripple peak value, effective value, and the load current. Please pay attention that all data are instant values, their actual values range around the instant values.

Load Current(mA) V2 V1
Vpp(mV) Vrms(mV) Vpp(mV) Vrms(mV)
0 240 16 250 14
200 360 52 450 65
400 410 72 550 82
600 450 86 600 92

You can see the real output ripple in the 600mA load current as below two pictures.

V2 Module 

V1 Module

Test 2: AC Input 220V 50Hz with a 470uF/16V filter capacitor accessing

The table below shows the relation of the output ripple peak value, effective value, and the load current. Please pay attention that all data are instant values, their actual values range around the instant values.

Load Current(mA) V2 V1
Vpp(mV) Vrms(mV) Vpp(mV) Vrms(mV)
0 110 11 140 10
200 160 26 280 30
400 200 36 300 40
600 230 42 350 44

You can see the real output ripple in the 600mA load current as below two pictures.

V2 Module

V1 Module

Test 3: AC Input 220V 50Hz with two 470uF/16V filter capacitors

The table below shows the relation of the output ripple peak value, effective value, and the load current. Please pay attention that all data are instant values, their actual values range around the instant values.

Load Current(mA) V2 V1
Vpp(mV) Vrms(mV) Vpp(mV) Vrms(mV)
0 100 9 150 8
200 120 18 250 24
400 140 22 280 30
600 150 27 350 34

You can see the real output ripple in the 600mA load current as below two pictures.

V2 Module

V1 Module

Test 4: Output Voltage in different load current

From the figure above, it is safe to say that the output capacity of these two modules is about the same.

Summary

According to the tests above, in the situation with no external filter capacitor, both two modules have big ripple. However, when they have two filter capacitors accessed, the output of V2 module has an obvious improvement and the output ripple of V2 module is smaller tham V1 module. Therefore, V2 module has a better performance than V1 module and meets the normal power supply input requirements.